Linux Disk I/O error (ext4)

Error Message

kernel: blk_update_request: I/O error, dev sda, sector 1953120 op 0x0:(READ) flags 0x0 phys_seg 1 prio class 0
kernel: EXT4-fs warning (device sda1): ext4_end_bio:343: I/O error 10 writing to inode 786433
kernel: critical medium error, dev sda, sector 1953120
kernel: Buffer I/O error on dev sda1, logical block 244140, lost async page write

Description

A disk I/O error means the kernel's block layer asked the storage device to read or write a sector and the device failed or returned bad data. The blk_update_request: I/O error line names the device and sector; the accompanying EXT4-fs / Buffer I/O error lines show the filesystem reacting to the failed block. Unlike a full disk (ENOSPC) or a permissions issue, this is a storage-reliability fault: a failing drive, a bad cable/controller, a degraded SAN/cloud volume, or media errors. Left unaddressed it leads ext4 to abort the journal and remount read-only, and risks data loss.

Technologies

  • linux (block layer, ext4, storage device drivers)

Severity

critical β€” I/O errors mean reads may return corrupt data and writes may be silently lost, putting data integrity at risk. They commonly cascade into an emergency read-only remount (full service outage) and, on the root device, into an unbootable system. Treat any sustained I/O error as a failing-disk incident.

Common Causes

  1. A physically failing drive β€” reallocated/pending sectors, media/medium errors (the device itself reports critical medium error).
  2. A bad SATA/SAS/NVMe cable, backplane, or HBA/controller corrupting transfers.
  3. A degraded or detached cloud block volume / SAN LUN (network storage that went away or returned errors).
  4. Controller/driver firmware bugs or a RAID array in a degraded/failed state.
  5. Overheating or power issues causing the device to drop off the bus.

Root Cause Analysis

When the block layer submits a request, the device driver returns the completion status. A non-zero error (-EIO) makes the kernel log blk_update_request: I/O error with the exact dev and sector. ext4, which had queued that block for a journal commit or page writeback, then logs EXT4-fs ... I/O error or Buffer I/O error ... lost async page write β€” meaning a dirty page could not be persisted and its data is now lost from durable storage. If the journal commit itself fails, ext4 invokes its errors=remount-ro policy. SMART attributes (Reallocated_Sector_Ct, Current_Pending_Sector, Offline_Uncorrectable) typically show the device degrading before total failure β€” confirming hardware, not software, as the cause.

Diagnostic Commands

# The authoritative evidence: I/O errors, device, sector, ext4 reaction
dmesg -T | grep -iE 'i/o error|blk_update_request|medium error|ext4-fs (error|warning)|buffer i/o'

# Drive health and the telltale failing-sector counters
sudo smartctl -a /dev/sda | grep -iE 'health|reallocated|pending|uncorrectable|crc'

# Run/read the drive self-test log
sudo smartctl -l selftest /dev/sda

# Which device/partition maps to the failing node, and the mount
lsblk -o NAME,SIZE,TYPE,MOUNTPOINT,MODEL
findmnt /dev/sda1

# RAID array state, if applicable
cat /proc/mdstat 2>/dev/null

Expected Results

$ dmesg -T | grep -i 'i/o error'
blk_update_request: I/O error, dev sda, sector 1953120 op 0x0:(READ)
critical medium error, dev sda, sector 1953120

$ smartctl -a /dev/sda | grep -i pending
197 Current_Pending_Sector  0x0032   100   100   000   ...  -  48
198 Offline_Uncorrectable   0x0030   100   100   000   ...  -  48

Non-zero Current_Pending_Sector / Offline_Uncorrectable, or a SMART overall health of FAILED, confirms the drive is dying. Repeating errors on the same sector point at media defects; errors across random sectors with CRC errors point at cabling/controller.

Resolution

  1. Treat it as a hardware incident. Back up / snapshot data immediately while the device is still partly readable β€” every further access risks more loss.
  2. Identify the device from dmesg/smartctl. If SMART shows failing/pending sectors or FAILED health, plan to replace the drive (or detach/replace the cloud volume).
  3. For a RAID array, replace the failed member and let it rebuild (/proc/mdstat shows resync); for cloud, restore from snapshot to a healthy volume.
  4. After replacement, restore data and run fsck on the new device to clear any metadata damage. Risk: never run fsck on a physically failing disk β€” it can finish the job of destroying it; copy data off first.
  5. If the cause is cabling/controller (CRC errors, random sectors), reseat/replace the cable or HBA before condemning the drive.

Validation

dmesg -T | grep -i 'i/o error' | tail   # expect: no new errors after replacement
sudo smartctl -H /dev/sdX               # expect: PASSED on the replacement
findmnt /dev/sdX1                        # filesystem mounts rw cleanly

Prevention

  • Run scheduled SMART self-tests and alert on reallocated/pending/CRC counters.
  • Use redundancy (RAID/replication, multi-AZ volumes) so one disk failure is survivable.
  • Maintain tested backups/snapshots; assume any disk can fail.
  • Monitor dmesg for I/O error and page it immediately β€” it rarely improves.
  • Replace drives proactively past their reliability window; track temperatures.