clarify IfcPointByDistanceExpression.OffsetVertical, -Lateral, -Longitudinal
before-NWIIssue to be resolved before the IFC NWI (New Work Item) submission to the next ISO cycle.Issue to be resolved before the IFC NWI (New Work Item) submission to the next ISO cycle.IFTo be checked with IFC Implementers ForumTo be checked with IFC Implementers ForumStatus: Open.#1143 In buildingSMART/IFC4.x-development;Proposed changes to IfcGridPlacement and IfcLinearPlacement
before-NWIIssue to be resolved before the IFC NWI (New Work Item) submission to the next ISO cycle.Issue to be resolved before the IFC NWI (New Work Item) submission to the next ISO cycle.IFTo be checked with IFC Implementers ForumTo be checked with IFC Implementers ForumStatus: Open.#1142 In buildingSMART/IFC4.x-development;- Status: Open.#1141 In buildingSMART/IFC4.x-development;
- Status: Open.#1133 In buildingSMART/IFC4.x-development;
Qto_SlabBaseQuantities: Rename Width to Thickness to avoid confusion with Depth
after-NWIIssue to be resolved after the IFC NWI (New Work Item) submission to the next ISO cycle.Issue to be resolved after the IFC NWI (New Work Item) submission to the next ISO cycle.iso-compatibilityIssue affects ISO compatibility policy for IFCIssue affects ISO compatibility policy for IFCiso-TeThe type of update at ISO: Technical (iso-Te), Editorial (iso-Ed) or General (iso-Ge)The type of update at ISO: Technical (iso-Te), Editorial (iso-Ed) or General (iso-Ge)Status: Open.#1089 In buildingSMART/IFC4.x-development;IfcConstraint Usage for As-built/complete models
ifc-update-outIssue out of scope for next ISO update (e.g. due to STEP tech, compatibility or other reasons)Issue out of scope for next ISO update (e.g. due to STEP tech, compatibility or other reasons)Status: Open.#1088 In buildingSMART/IFC4.x-development;Status in Pset_ProvisionForVoid
ifc-update-outIssue out of scope for next ISO update (e.g. due to STEP tech, compatibility or other reasons)Issue out of scope for next ISO update (e.g. due to STEP tech, compatibility or other reasons)legacyProbably poor naming, but used to tag issues from pre-4.3 eraProbably poor naming, but used to tag issues from pre-4.3 eraStatus: Open.#1086 In buildingSMART/IFC4.x-development;datatype "IfcPressureMeasure" for "SecondaryAirFlowRateRange"
after-NWIIssue to be resolved after the IFC NWI (New Work Item) submission to the next ISO cycle.Issue to be resolved after the IFC NWI (New Work Item) submission to the next ISO cycle.iso-compatibilityIssue affects ISO compatibility policy for IFCIssue affects ISO compatibility policy for IFCiso-TeThe type of update at ISO: Technical (iso-Te), Editorial (iso-Ed) or General (iso-Ge)The type of update at ISO: Technical (iso-Te), Editorial (iso-Ed) or General (iso-Ge)Status: Open.#1084 In buildingSMART/IFC4.x-development;