End-to-end Industrial IoT condition monitoring system for rotating equipment from OPC UA data acquisition to real-time ML anomaly detection, fault diagnosis, and automated maintenance alerts.
Built as an industry-oriented portfolio project demonstrating a production-style Industry 4.0 architecture on a fully containerized local deployment.
Industrial pumps and rotating machinery fail unexpectedly, causing costly unplanned downtime. This platform continuously monitors a simulated industrial pump (Pump-01), detects early signs of degradation using machine learning, identifies the probable fault mechanism, and alerts the maintenance team before failure occurs.
The system follows a production-style IIoT architecture using OPC UA for industrial data acquisition, MQTT for data distribution, time-series storage, real-time dashboards, and automated maintenance notifications.
┌──────────────────────────────────────────────────────────────────────┐
│ FIELD / EDGE LAYER │
│ │
│ Python Pump Simulator ──► OPC UA Server (asyncua, port 4840) │
│ (5 fault profiles, Exposes: Temperature, Vibration, │
│ stochastic behavior, Current, Mode via standard OPC UA │
│ 4-min degradation cycle) address space │
└─────────────────────────────┬────────────────────────────────────────┘
│ opc.tcp://simulator:4840
▼
┌─────────────────────────────────────────────────────────────────────┐
│ GATEWAY / EDGE LAYER │
│ │
│ Node-RED │
│ ├─ OPC UA Client ──► reads sensor values every second │
│ ├─ Protocol bridge: OPC UA → MQTT │
│ ├─ Alarm logic & preprocessing │
│ └─ Publishes to: factory/pump01/state │
└─────────────────────────────┬───────────────────────────────────────┘
│ MQTT (Mosquitto, port 1883)
▼
┌──────────────────┐ ┌─────────────────────────────────────────────┐
│ MQTT Broker │ │ SUBSCRIBERS │
│ Mosquitto │───►│ │
│ │ │ ┌─────────────────────────────────────┐ │
│ Topic: │ │ │ ML Service (Python) │ │
│ factory/pump01/ │ │ │ ├─ Phase 1: Online calibration │ │
│ state │ │ │ │ (IsolationForest, 100 samples) │ │
│ │ │ │ ├─ Phase 2: Anomaly detection │ │
│ factory/pump01/ │ │ │ ├─ Phase 3: Fault diagnosis │ │
│ ml_diagnostics │ │ │ │ (physics-informed scoring) │ │
│ │ │ │ └─ Publishes: severity, hypothesis, │ │
│ │ │ │ recommendation │ │
│ │ │ └─────────────────────────────────────┘ │
│ │ │ │
│ │ │ ┌─────────────────────────────────────┐ │
│ │ │ │ Node-RED → InfluxDB Writer │ │
│ │ │ │ Stores: sensor data + ML output │ │
│ │ │ └─────────────────────────────────────┘ │
│ │ │ │
│ │ │ ┌─────────────────────────────────────┐ │
│ │ │ │ Telegram Bot API │ │
│ │ │ │ Fires on: WARNING / CRITICAL │ │
│ │ │ └─────────────────────────────────────┘ │
└──────────────────┘ └─────────────────────────────────────────────┘
│
▼ InfluxDB (port 8086)
┌─────────────────────────────────────────────────────────────────────┐
│ Grafana Dashboard (port 3000) │
│ ├─ Sensor time series: Temperature, Vibration, Current │
│ ├─ Machine Status panel: NORMAL / WARNING / CRITICAL │
│ ├─ Dominant Sensor bar gauge (Z-score deviation) │
│ ├─ Fault Hypothesis: bearing_wear, misalignment, cavitation... │
│ └─ Maintenance Recommendation with priority and action code │
└─────────────────────────────────────────────────────────────────────┘
| Layer | Technology | Purpose |
|---|---|---|
| Device simulation | Python 3.11, asyncua | Industrial pump simulator with OPC UA server |
| Field protocol | OPC UA (IEC 62541) | Standard industrial device communication |
| Edge gateway | Node-RED 5.0.4 | Protocol bridging, preprocessing, alarm logic |
| Message broker | Eclipse Mosquitto 2.0 | MQTT pub/sub backbone |
| ML service | Python, scikit-learn | Online anomaly detection + fault diagnosis |
| Time-series DB | InfluxDB 2.7 | Sensor and diagnostic data storage |
| Visualization | Grafana 10.4 | SCADA-style live dashboards |
| Notifications | Telegram Bot API | Maintenance team alerts |
| Containerization | Docker + Docker Compose | Full-stack single-command deployment |
The ML service implements a two-stage online pipeline => no pre-trained model files, no offline dataset required.
Stage 1 => Anomaly Detection (IsolationForest, unsupervised)
The service self-calibrates during the first 100 readings of normal operation(this requires launching the ml_service first then the simulator ), fitting an IsolationForest model in memory. After calibration, every incoming reading is scored against the learned normal operating envelope. Output: continuous anomaly score.
No fault labels are needed. The model learns what "normal" looks like and flags deviations.
Stage 2 => Fault Diagnosis (physics-informed signature matching)
Once an anomaly is confirmed, the service analyzes which sensors deviated and how. Using engineering-informed sensor signatures consistent with condition-monitoring and fault-diagnosis principles. The approach is conceptually aligned with condition-monitoring and fault-diagnosis practices described in ISO 13373-1 and ISO 13379-1. Each fault hypothesis receives a continuous support score:
| Fault | Key signature |
|---|---|
| Bearing wear | Vibration dominant + moderate temperature rise |
| Misalignment | Vibration + elevated current together |
| Cavitation | High vibration variability + impulsive spikes |
| Motor / Electrical | Current dominant + temperature rise |
| Impeller imbalance | Vibration dominant, isolated |
Output includes most likely fault, confidence level (HIGH/MEDIUM/LOW), two alternatives, and a specific maintenance recommendation.
Important note: This is a proof-of-concept demonstrating the pipeline architecture. Diagnosis uses physics-based scoring, not a trained classifier. In a production deployment, the simulator would be replaced with real sensors and frequency-domain features would be added for precise bearing defect identification.
The Python simulator generates realistic stochastic sensor data with temporal correlation (AR1 process), simulating a 4-minute degradation cycle:
- 0–120s: Normal operation => stable readings with realistic noise
- 120–200s: Progressive degradation => gradual drift with increasing variability
- 200–240s: Fault imminent => severe anomalies, high deviation
- Stops: Does not auto-restart => simulates maintenance intervention
Each run randomly selects a fault profile from 5 options. The ML service never receives the fault label, it must infer the fault type from sensor patterns alone.
Requirements: Docker Desktop, Git
# Clone the repository
git clone https://github.com/idsabdo/IIoT-Predictive-Maintenance-Platform
cd IIoT-Predictive-Maintenance-Platform
# Copy environment file and configure credentials
cp .env.example .env
# Edit .env with your InfluxDB credentials and Telegram bot token
# Start all services
docker compose up -d
# Check all 6 containers are running
docker compose ps
# Restart the simulator to begin a new simulation cycle
docker restart simulatorAccess the interfaces:
| Service | URL | Default credentials |
|---|---|---|
| Grafana | http://localhost:3000 | See your .env file |
| InfluxDB | http://localhost:8086 | See your .env file |
| Node-RED | http://localhost:1880 | No auth |
Watch the ML service calibrate:
docker logs ml_service --followRestart a simulation cycle after it completes:
docker restart simulatorIIoT-Predictive-Maintenance-Platform/
│
├── simulator/ # Industrial pump simulator + OPC UA server
│ ├── simulator.py # Pump physics, fault profiles, OPC UA server
│ ├── requirements.txt
│ └── Dockerfile
│
├── ml_service/ # ML anomaly detection + fault diagnosis
│ ├── ml_service.py # IsolationForest + physics-informed scoring
│ ├── requirements.txt
│ └── Dockerfile
│
├── mosquitto/ # MQTT broker configuration
│ └── config/
│ └── mosquitto.conf
│
├── grafana/ # Dashboard provisioning
│ └── provisioning/
│ ├── datasources/
│ └── dashboards/
│
├── nodered_data/ # Node-RED flows (exported)
│
├── docs/ # Screens of the System architecture, Dashboard and Telegram notifications
│
│
├── docker-compose.yml # Full stack orchestration
├── .env.example # Environment variable template
├── .gitignore
└── README.md
The simulator saves the actual hidden fault type to simulation_ground_truth.csv after each run. This allows post-run comparison between ML diagnosis and actual fault, useful for evaluating diagnostic accuracy across different fault types.
This architecture directly maps to real industrial deployments:
- OPC UA is a widely adopted communication protocol for Siemens, ABB, and Rockwell PLCs, your Node-RED acts as an OPC UA client exactly as edge gateways do in production
- MQTT is the standard for IIoT data distribution (AWS IoT, Azure IoT Hub, Sparkplug B all use MQTT)
- Online ML calibration Startup self-calibration enables unsupervised anomaly detection without requiring labeled failure data for each new machine.
- Telegram notifications provides an external notification channel for maintenance alerts, representing the type of operator/mobile notification used around industrial alarm workflows.
Sectors where this architecture applies directly: mining (OCP, Managem), automotive (LEONI, Stellantis Kenitra), water utilities (ONEE, AMENDIS), and any plant with rotating equipment.
- Sampling rate: 1Hz real vibration analysis for bearing fault detection uses 5–50kHz for frequency-domain signatures. At 1Hz, only statistical/trend features are available.
- Synthetic data: The simulator generates plausible but not validated physics. Fault profiles are engineering-informed estimates, not calibrated against real pump measurements.
- 3 sensors: Production systems use multiple accelerometer positions and often acoustic emission sensors.
- Diagnosis method: Physics-based scoring, not a trained classifier. Discrimination between bearing and misalignment is inherently limited at 1Hz with 3 sensors.